TECHNICAL SPECIFICATIONS FOR 15 AMP AND 30 AMP MODULES |
|||
• |
Input Power | ||
| 180-260 Volts AC; 50-60 Hertz | |||
• |
Output Power | ||
| Solid State Relay, 15 Amps Module, Max.3.5 KW (Resistive) at 230 Volts AC, 30Amps Module 7 KW (Resistive) at 230 Volts AC | |||
• |
Protection | ||
| 15 Amp Heater Fuse; 500mA Control Mains Fuse; MOVs and Auto Inhibits
30 AMP : 500mA Controller Fuse ;MOVs AUTO-INHIBITS ;30A MCB |
|||
• |
Soft Start Function | ||
| Auto ramp-up heater warm function at startup and at < 100 deg C -- WITH auto time out and tranfer to normal mode | |||
| a. Fully automatic, overriding Auto & Manual Modes
b. Duration : Maximum 10 minutes |
|||
• |
R. F. Interference | ||
| Nil : Solid State zero-crossed output | |||
• |
Temperature Range | ||
| 0-499°C. Limited to protect heater . Output disabled over 500 deg C. | |||
• |
Display | ||
| 3-Digit, Hi-Brightness LED
DISPLAY flashes on Manual mode and indicates % Power applied to Heater. Hi Briteness LEDs for LOAD , OPEN T/C,REV T/C ,MANUAL MODE . |
|||
• |
Sensor Type | ||
| Type 'J' Standard [Industry Standard]
Type 'K' Thermocouples: On request | |||
• |
Set-Point Control | ||
| Digital Thumbwheel, 0-499°C
Locked at 499 deg C to ensure Heater safety Higher Temperatures upto 999 Deg C available on request. |
|||
• |
MANUAL | ||
| MANUAL knob sets % Power in MAN Mode | |||
• |
Display Resolution | ||
| 1 deg C | |||
• |
Control Accuracy | ||
| BETTERTHAN 0.5°C | |||
• |
Control Loop | ||
| Pulse Width Modulated PID | |||
• |
Mode Selection | ||
| Auto, Manual | |||
• |
Manual Operation | ||
| 10% to 90% of full Output Power Overriding Auto Mode but all safeties are enabled | |||
• |
Thermocouple Compensation | ||
| Automatic Internal self-compensation No recalibration necessary for Life | |||
• |
Output Connections | ||
| Integrated Multipin Locking Connectors Separate connectors for Heaters and Thermocouples in Multizone units | |||
• |
Enclosures | ||
| Modules :Hard coated, Heavy gauge, brushed, plating grade anodized Aluminum panels | |||
• |
Chassis : | ||
| Heavy Steel, CNC cut and welded , powder-coated Professional Multimodule racks. Multizone are Force Ventilated |
|||